Fittings and Delivery of your Rainwater Tank

Fittings

Round Rainwater Tanks

Polymaster Round Rainwater Tanks come standard with the fittings shown on the table below.

The size of the fittings, and Standard and Optional fitting locations around the tank are also shown on this table.

Product Details



CodeStrainer 200mmStrainer 300mmStrainer 400mmOverflow 90mmOutlet 25mm & Ball ValveOutlet 40mm & Ball Valve
RWT200 centre

12.00 6.00 standard
RWT600 centre

12.00 6.00 standard
RWT1000 centre

12.00 6.00 standard
RWT1600
12.00
11.00 std/4.00 6.00 standard
RWT2270T
12.00
11.00 std/5.00 6.00 standard
RWT2270LP
12.00
11.00 std/4.00 6.00 standard
RWT3300
12.00
11.00 std/4.00 6.00 standard
RWT4500T

12.00 11.00 std/4.00 6.00 standard
RWT4500LP

12.00 11.00 std/3.00/7.00 6.00 standard
RWT5000

12.00 11.00 std/4.00 6.00 standard
RWT7100

12.00 11.00 std/3.00/7.00
6.00 standard
RWT9000

12.00 11.30 std/2.30/5.30/8.30
6.00 standard
RWT13600

12.00 11.00 std/2.00/5.00/8.00
4.00 standard
RWT22500

12.00 11.30 std/2.30/5.30/8.30
4.00 standard
RWT31700

12.00 11.30 std/2.30/5.30/8.30
4.00 standard

This diagram on the below helps to explain the fitting locations.

round tank diagram

Slendaline™ Rainwater Tanks

Polymaster Slendaline™ Rainwater Tanks come standard with the fittings shown on the table below.

The size of the fittings, and Standard and Optional fitting locations around the tank are also shown on this table.

Product Details


CodeStrainer 200mmStrainer 400mmOverflow 90mm25mm Outlet & Bibcock25mm Outlet & Ball Valve
SLT600 centre
6.00 7:00 std/1:00 Alt.
SLT1050 centre
6.00 7:00 std/1:00 Alt.
SLT2100
centre 6:00 std/12:00 Alt.
7:00 std/11:00, 1:00 Alt.
SLT2100AP
centre 6:00 std/12:00 Alt.
7:00 std/11:00, 1:00 Alt.
SLT2100GP
centre 6:00 std/12:00 Alt.
7:00 std/11:00, 1:00 Alt.

This diagram on the below helps to explain the fitting locations.

Slendaline tank diagram

Slendastyle™ Rainwater Tanks

Polymaster Slendastyle™ Rainwater Tanks come standard with the fittings shown on the table below.

The size of the fittings, and Standard and Optional fitting locations around the tank are also shown on this table.

Product Details


CodeStrainer 300mmStrainer 400mmOverflow 90mm25mm Outlet & Ball Valve
SLST600 6:00 std/12:00 Alt
12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST1050
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST2000
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST2000AP
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST2000GPS
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST3000
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST3000AP
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt
SLST3000GPS
6:00 std/12:00 Alt 12:00 std/6:00 Alt 6:00 std/12:00 Alt

This diagram on the below helps to explain the fitting locations.

Slendastyle tank diagram

Delivery

Polymaster’s large tanks can be delivered direct to property where there is a properly made road and large turning area available. It is the owner’s responsibility to provide clear access to site, and to secure tank/s once left at site.

If the driver cannot reach the location, the tank/s will be left at the closest practical position at the driver’s discretion.

Free delivery to site: 13,600 ltr, 22,500 ltr, 31,700 ltr (remote areas excluded)
Free to store: all other tanks (most areas).
(Any delivery can be arranged, please call to discuss).

Delivery requirements

Clearance for truck and trailer 19 metres long, 5 metres high, 3.5 metres wide

  • In accordance with OH&S requirements, the customer must be present at the time of delivery. If this is not possible, arrangement must be made with the distributor, friends or neighbours to ensure truck driver will have the necessary assistance as listed below.
  • A minimum of three able bodied persons to help the driver place tanks 13,600 ltr and larger. This is to be arranged by the customer receiving the tank/s.
  • Underground tanks will require a lifting device (forklift etc) to unload. This is not supplied by the driver.

Installation

Installation diagram

Installation Guide

Entry to tank is not required when installing a Polymaster! Never enter a tank alone. Have an attendant stand by. Restricted Space - only enter after carrying out a Hazard Identification Risk Assessment (H.I.R.A.).

  • The tank site must be firm, level and flat, a concrete type base well compacted and free from any rocks, stones and sharp objects.
  • A concrete pad is recommended and must be greater than the diameter of the tank. If not, a 75mm (3”) compacted sand base, or other consolidated fill i.e. crusher dust, may be used as a tank pad.
  • If a compacted sand base or other consolidated fill is used, a retaining wall or surround must be provided to prevent erosion and may alter the specifiations of the tank.
  • The overflow must be piped well clear of the tank to avoid any undermining of the tank base.
  • Ensure that a flexible hose of at least 300 mm (12”) is installed after the tank valve to absorb any shocks or movement.
  • If tank is placed on a stand, support pipework off the stand, never support pipework off the tank.

Note: Failure to properly install tank as per instructions will void warranty.

Calculator


Calculate your Water Catchment.
more info

Calculate your Water Catchment
Fill our the form and click the button to calculate your water catchment amount.
Roof Area (m2)
Rain Fall (mm)
close