Search

Closed Head Drums

Polymaster’s closed head drums are a safe and effective solution for storing and dosing aggressive chemicals, including chlorine. Available in 110L and 210L, with and without an integrated bund, they allow you to decant, store, mix, and dispense chemicals on site.

Manufactured from UV-stabilised polyethylene, these tanks will not corrode when used with aggressive chemicals, giving you greater security on site. Available with or without secondary containment bunding.

C&I - Customer Service Team Member

SPECIFICATIONS

Chemical Dosing Unit Specifications

Polymaster’s closed head drum range is available in two capacities with bunded and non-bunded configurations. All tanks are rated for contents up to 1.5SG and comply with AS3780-2008 and AS/NZS 4766:2020.

Code Product Diameter (mm)Height (mm)
110L Closed Head DrumCHD110110L Closed Head Drum500675Download Data Sheet
Download Drawing
Download STEP File
110L Closed Head Drum (Bund)CHD110+Bund110L Closed Head Drum (Bund)500678Download Data Sheet
Download Drawing
Download STEP File
210L Closed Head DrumCHD210210L Closed Head Drum580930Download Data Sheet
Download Drawing
Download STEP File
210L Closed Head Drum (Bund)CHD210+Bund210L Closed Head Drum (Bund)580935Download Drawing
Download STEP File
110L Closed Head Drum

110L Closed Head Drum

CHD110

Specifications
Diameter (mm)500
Height (mm)675
110L Closed Head Drum (Bund)

110L Closed Head Drum (Bund)

CHD110+Bund

Specifications
Diameter (mm)500
Height (mm)678
210L Closed Head Drum

210L Closed Head Drum

CHD210

Specifications
Diameter (mm)580
Height (mm)930
210L Closed Head Drum (Bund)

210L Closed Head Drum (Bund)

CHD210+Bund

Specifications
Diameter (mm)580
Height (mm)935


Not sure which configuration is right for your application?

Call our team on 1800 062 064 to discuss your chemical storage and dosing requirements.

Designed for Chlorine Dosing and Aggressive Chemical Storage

The ideal set-up for dosing chlorine in an easy-to-use system is for a dosing pump to be mounted directly to a Polymaster closed head drum. The flat, rigid top with 4 x 8mm stainless nutserts as standard makes pump mounting straightforward, and the provision for a generic stainless pump mounting bracket means integration with common dosing pump systems is simple. 

Standard features across the range: 

  • Improved top of tank design, remains flat and rigid 
  • 4 x 8mm stainless nutserts in top as standard 
  • Designed for contents of up to 1.5SG 
  • Provision for generic stainless pump mounting bracket 
  • Custom outlet connections available 
  • Convex base for complete drainage 
  • Calibrated volume indication, moulded in permanently 
  • Stackable for storage 

Estimation and Engineering

Every Polymaster closed head drum is designed for demanding chemical dosing environments. Here are the key features built into every unit.

UV-Stabilised Polyethylene

Will not corrode when used with aggressive chemicals, including chlorine. Suitable for indoor and outdoor use.

1.5SG Rated

Designed for contents of up to 1.5 specific gravity, suitable for a wide range of liquid chemicals.

Calibrated Volume Indication

Moulded-in volume markings are permanent and will not wear or fade over the life of the tank.

Stackable for Storage

Units can be stacked when empty, making them practical for storage and transport.

We're Here to Help You Understand Chemical Tank Requirements

Selecting the right chemical dosing setup requires matching the tank capacity, material compatibility, and secondary containment requirements to your specific application. Our team can help you work through those requirements before you order.

COMPACT / SLIP-ON FIRE FIGHTING UNITS

Integrated Bund Options for Secondary Containment

The CHD110+BUND and CHD210+BUND variants include an integrated bund designed to contain any leakage or spillage from the tank. This is required under AS3780-2008, The Storage and Handling of Corrosive Substances, for sites storing corrosive liquids where spill containment is mandatory.

 

Using an integrated bunded unit removes the need to construct a separate earth or concrete bund around a standalone tank. The bund is moulded as part of the unit, so there are no joins or penetrations to maintain. This is a practical option for indoor chemical rooms, outdoor dispensing areas, and applications where the tank may need to be relocated.

Established in Australia and Trusted for Decades


Polymaster has been manufacturing poly storage solutions for Australian industrial, agricultural, and water treatment applications for over 30 years. Our closed head drums are manufactured in Australia, certified to relevant Australian Standards, and supported by a national network of more than 1,600 distributor stores.

APPLICATIONS

Where Closed Head Drums Are Used

water treatment

Water Treatment and Chlorination

The most common application for Polymaster closed head drums is chlorine dosing in water treatment. The tank’s UV-stabilised polyethylene construction resists chlorine corrosion, and the flat top with stainless nut inserts is designed for direct pump mounting.

Chemical Transfer Station

Chemical Storage and Dispensing

Suitable for storing and dispensing a wide range of liquid chemicals rated to 1.5SG. The convex base ensures complete drainage, and the calibrated volume markings allow accurate stock monitoring without removing the lid.

Chemical dosing

Odour Control and pH Correction

Used in industrial water treatment, aquaculture, and wastewater applications for metered dosing of odour control and pH correction chemicals. The integrated bund option is suitable for sites where secondary containment is required under AS3780-2008.

Standards and Certifications

All Polymaster closed head drums comply with the following Australian Standards.

AS3780-2008

The Storage and Handling of Corrosive Substances. This standard governs the safe storage and handling of corrosive liquids, including requirements for secondary containment.

AS/NZS 4766:2020

Polyethylene Storage Tanks for Water and Chemicals. Covers design, manufacture, and performance requirements for poly tanks used with water and chemicals.

AS/NZS 4020:2018

Testing of Products for Use in Contact with Drinking Water. Applicable where tanks may be used in potable water treatment applications.

 

ISO 9001

Polymaster holds ISO 9001 quality management certification. All tanks are manufactured under an ISO 9001 certified quality system.

Not Sure Which Tank You Need?

Talk to our team. We’ll help you match the right closed head drum size and configuration to your chemical dosing or storage requirements.

Ag - Customer Service Team Member

FAQs

Frequently Asked Questions

Common questions about Polymaster’s closed head drum range.

An open head drum has a fully removable lid, making it suitable for storing solids, semi-solids, or products that need direct access for filling or mixing. A closed head drum has a fixed top with small bung openings for filling and dispensing, making it better suited to liquid chemical storage where containment of vapours and odours is important. Polymaster closed head drums are designed for liquid chemical dosing applications, including chlorine and other corrosive substances.

Polymaster closed head drums are primarily used for chemical dosing applications, including chlorine dosing in water treatment, pH correction, odour control, and the storage and dispensing of liquid chemicals rated to 1.5SG. The flat top with stainless nutserts is designed to accept a mounted dosing pump, making the unit a complete dispensing solution.

 

The openings in a closed head drum are called bungs. Polymaster closed head drums include a threaded 20mm outlet with a drain plug. Custom outlet connections are also available on request.

Whether a bund is required depends on your application and the relevant Australian Standard. AS3780-2008, The Storage and Handling of Corrosive Substances, requires secondary containment for sites storing corrosive liquids above certain thresholds. Polymaster offers the CHD110+BUND and CHD210+BUND variants with an integrated bund for applications where secondary containment is required or preferred. Contact our team or your local safety regulator for guidance specific to your site.

Polymaster closed head drums are manufactured from UV-stabilised polyethylene and are rated for liquid chemicals up to 1.5 specific gravity. Common applications include chlorine, hypochlorite, pH correction chemicals, and other corrosive substances used in water treatment. For specific chemical compatibility, contact our team with the chemical you intend to store. Not all chemicals are compatible with polyethylene, and some may require a different tank material.

Ask a Specialist

Fill in the form below and a specialist will be in touch within 24 hours to discuss your needs and answer any questions.

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*

This site is protected by reCAPTCHA.

Download Step File

Fill in your information below, the STEP form will be sent to you for download via email.

Download Step File Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Postcode
Country

This site is protected by reCAPTCHA.