Home Chemical & Industrial Chemical Dosing Closed Head Drums
Closed Head Drums
Polymaster’s closed head drums are a safe and effective solution for storing and dosing aggressive chemicals, including chlorine. Available in 110L and 210L, with and without an integrated bund, they allow you to decant, store, mix, and dispense chemicals on site.
Manufactured from UV-stabilised polyethylene, these tanks will not corrode when used with aggressive chemicals, giving you greater security on site. Available with or without secondary containment bunding.
SPECIFICATIONS
Chemical Dosing Unit Specifications
Polymaster’s closed head drum range is available in two capacities with bunded and non-bunded configurations. All tanks are rated for contents up to 1.5SG and comply with AS3780-2008 and AS/NZS 4766:2020.
| Code | Product | Diameter (mm) | Height (mm) | ||
|---|---|---|---|---|---|
![]() | CHD110 | 110L Closed Head Drum | 500 | 675 | Download Data Sheet Download Drawing Download STEP File |
![]() | CHD110+Bund | 110L Closed Head Drum (Bund) | 500 | 678 | Download Data Sheet Download Drawing Download STEP File |
![]() | CHD210 | 210L Closed Head Drum | 580 | 930 | Download Data Sheet Download Drawing Download STEP File |
![]() | CHD210+Bund | 210L Closed Head Drum (Bund) | 580 | 935 | Download Drawing Download STEP File |
110L Closed Head Drum
CHD110
110L Closed Head Drum (Bund)
CHD110+Bund
210L Closed Head Drum
CHD210
210L Closed Head Drum (Bund)
CHD210+Bund
Not sure which configuration is right for your application?
Call our team on 1800 062 064 to discuss your chemical storage and dosing requirements.
Designed for Chlorine Dosing and Aggressive Chemical Storage
The ideal set-up for dosing chlorine in an easy-to-use system is for a dosing pump to be mounted directly to a Polymaster closed head drum. The flat, rigid top with 4 x 8mm stainless nutserts as standard makes pump mounting straightforward, and the provision for a generic stainless pump mounting bracket means integration with common dosing pump systems is simple.
Standard features across the range:
- Improved top of tank design, remains flat and rigid
- 4 x 8mm stainless nutserts in top as standard
- Designed for contents of up to 1.5SG
- Provision for generic stainless pump mounting bracket
- Custom outlet connections available
- Convex base for complete drainage
- Calibrated volume indication, moulded in permanently
- Stackable for storage
Estimation and Engineering
Every Polymaster closed head drum is designed for demanding chemical dosing environments. Here are the key features built into every unit.
UV-Stabilised Polyethylene
Will not corrode when used with aggressive chemicals, including chlorine. Suitable for indoor and outdoor use.
1.5SG Rated
Designed for contents of up to 1.5 specific gravity, suitable for a wide range of liquid chemicals.
Calibrated Volume Indication
Moulded-in volume markings are permanent and will not wear or fade over the life of the tank.
Stackable for Storage
Units can be stacked when empty, making them practical for storage and transport.
We're Here to Help You Understand Chemical Tank Requirements
Selecting the right chemical dosing setup requires matching the tank capacity, material compatibility, and secondary containment requirements to your specific application. Our team can help you work through those requirements before you order.
COMPACT / SLIP-ON FIRE FIGHTING UNITS
Integrated Bund Options for Secondary Containment
The CHD110+BUND and CHD210+BUND variants include an integrated bund designed to contain any leakage or spillage from the tank. This is required under AS3780-2008, The Storage and Handling of Corrosive Substances, for sites storing corrosive liquids where spill containment is mandatory.
Using an integrated bunded unit removes the need to construct a separate earth or concrete bund around a standalone tank. The bund is moulded as part of the unit, so there are no joins or penetrations to maintain. This is a practical option for indoor chemical rooms, outdoor dispensing areas, and applications where the tank may need to be relocated.
Established in Australia and Trusted for Decades
Polymaster has been manufacturing poly storage solutions for Australian industrial, agricultural, and water treatment applications for over 30 years. Our closed head drums are manufactured in Australia, certified to relevant Australian Standards, and supported by a national network of more than 1,600 distributor stores.
APPLICATIONS
Where Closed Head Drums Are Used
Water Treatment and Chlorination
The most common application for Polymaster closed head drums is chlorine dosing in water treatment. The tank’s UV-stabilised polyethylene construction resists chlorine corrosion, and the flat top with stainless nut inserts is designed for direct pump mounting.
Chemical Storage and Dispensing
Suitable for storing and dispensing a wide range of liquid chemicals rated to 1.5SG. The convex base ensures complete drainage, and the calibrated volume markings allow accurate stock monitoring without removing the lid.
Odour Control and pH Correction
Used in industrial water treatment, aquaculture, and wastewater applications for metered dosing of odour control and pH correction chemicals. The integrated bund option is suitable for sites where secondary containment is required under AS3780-2008.
Standards and Certifications
All Polymaster closed head drums comply with the following Australian Standards.
AS3780-2008
The Storage and Handling of Corrosive Substances. This standard governs the safe storage and handling of corrosive liquids, including requirements for secondary containment.
AS/NZS 4766:2020
Polyethylene Storage Tanks for Water and Chemicals. Covers design, manufacture, and performance requirements for poly tanks used with water and chemicals.
AS/NZS 4020:2018
Testing of Products for Use in Contact with Drinking Water. Applicable where tanks may be used in potable water treatment applications.
ISO 9001
Polymaster holds ISO 9001 quality management certification. All tanks are manufactured under an ISO 9001 certified quality system.
“We’ve been really happy with the Polymaster Closed Head Drum. It’s a compact, practical setup for chemical dosing and the built-in volume markings and easy drainage make it simple to manage day to day.”
“The Polymaster Closed Head Drum has worked really well for our dosing setup. It’s well made, easy to use and the polyethylene construction gives us confidence when handling chemicals. A simple solution that does the job.”
Not Sure Which Tank You Need?
Talk to our team. We’ll help you match the right closed head drum size and configuration to your chemical dosing or storage requirements.
FAQs
Frequently Asked Questions
Common questions about Polymaster’s closed head drum range.
What is the difference between open and closed head drums?
An open head drum has a fully removable lid, making it suitable for storing solids, semi-solids, or products that need direct access for filling or mixing. A closed head drum has a fixed top with small bung openings for filling and dispensing, making it better suited to liquid chemical storage where containment of vapours and odours is important. Polymaster closed head drums are designed for liquid chemical dosing applications, including chlorine and other corrosive substances.
What is a closed head drum used for?
Polymaster closed head drums are primarily used for chemical dosing applications, including chlorine dosing in water treatment, pH correction, odour control, and the storage and dispensing of liquid chemicals rated to 1.5SG. The flat top with stainless nutserts is designed to accept a mounted dosing pump, making the unit a complete dispensing solution.
What is the opening in a closed head drum called?
The openings in a closed head drum are called bungs. Polymaster closed head drums include a threaded 20mm outlet with a drain plug. Custom outlet connections are also available on request.
Do I need a bund for my chemical dosing tank?
Whether a bund is required depends on your application and the relevant Australian Standard. AS3780-2008, The Storage and Handling of Corrosive Substances, requires secondary containment for sites storing corrosive liquids above certain thresholds. Polymaster offers the CHD110+BUND and CHD210+BUND variants with an integrated bund for applications where secondary containment is required or preferred. Contact our team or your local safety regulator for guidance specific to your site.
What chemicals can be stored in a Polymaster closed head drum?
Polymaster closed head drums are manufactured from UV-stabilised polyethylene and are rated for liquid chemicals up to 1.5 specific gravity. Common applications include chlorine, hypochlorite, pH correction chemicals, and other corrosive substances used in water treatment. For specific chemical compatibility, contact our team with the chemical you intend to store. Not all chemicals are compatible with polyethylene, and some may require a different tank material.