Storing and dispensing diesel on site, whether on a farm, a mine, a construction site or a transport yard, Polymaster’s self-bunded diesel tanks arrive as a single factory-fitted unit.

Three series, one standard: Australian-made double-wall construction, Italian Piusi pump technology, and plug-and-play setup. Each is a tank within a tank, with double poly walls containing any spill within the system and meeting AS1940 self-bunding requirements without a separate bund.

Ag - Customer Service Team Member

POLYMASTER SELF-BUNDED DIESEL FUEL TANK SOLUTIONS

Browse Our Range of Self-Bunded Diesel Fuel Tanks

Three series to match three levels of operational need. The Ranger and Quantum series are available in 5,000L and 10,000L. The Essential series is 10,000L only.

All share the same double-wall self-bunded construction, quality Piusi pump, and plug and play setup. The difference is in the control and monitoring capability you need on-site.

Code Product Capacity (L)
10,000L Self Bunded Diesel Tank – Essential SeriesDMDS10000E-240V10,000L Self Bunded Diesel Tank – Essential Series10,000Download Drawing
Download Data Sheet
Self Bunded Diesel Tank – Quantum SeriesDMDS5000 - 10000QSelf Bunded Diesel Tank – Quantum Series5,000 / 10,00010,000L Drawing
Download Data Sheet
Self Bunded Diesel Tank – Ranger SeriesDMDS5000 - 10000RSelf Bunded Diesel Tank – Ranger Series5,000 / 10,00010,000L Drawing
Download Data Sheet
Self Bunded Diesel Tank – Ranger Series – 12 VoltDMDS5000 - 10000R-12VSelf Bunded Diesel Tank – Ranger Series – 12 Volt5,000 / 10,00010,000L Drawing
Download Data Sheet
10,000L Self Bunded Diesel Tank – Essential Series

10,000L Self Bunded Diesel Tank – Essential Series

DMDS10000E-240V

Specifications
Capacity (L)10,000
Self Bunded Diesel Tank – Quantum Series

Self Bunded Diesel Tank – Quantum Series

DMDS5000 - 10000Q

Specifications
Capacity (L)5,000 / 10,000
Self Bunded Diesel Tank – Ranger Series

Self Bunded Diesel Tank – Ranger Series

DMDS5000 - 10000R

Specifications
Capacity (L)5,000 / 10,000
Self Bunded Diesel Tank – Ranger Series – 12 Volt

Self Bunded Diesel Tank – Ranger Series – 12 Volt

DMDS5000 - 10000R-12V

Specifications
Capacity (L)5,000 / 10,000

Not sure which series suits your operation?

Our team can help you match the right capacity and configuration to your site. Call us on 1800 062 064 or use the quote tool above.

SELF-BUNDED DIESEL TANK APPLICATIONS

Industries and Applications

Self-bunded diesel fuel tanks are used wherever diesel needs to be stored and dispensed on-site – safely, compliantly, and without the need for a separate bund structure. Polymaster’s range covers the most common site types across Australia.

Polymaster Diesel Transfer Tank and dispenser Filling tractor

Agriculture and Farming

On farm, diesel powers everything from tractors and harvesters to irrigation pumps and grain handling equipment. A self-bunded tank positioned near your machinery shed or in the paddock gives you fast, controlled access to fuel when you need it, with a digital fluid meter to track usage across vehicles. The Essential Series is a practical starting point for smaller operations; the Ranger suits larger fleets.

mining

Mining and Resources

Mining operations demand fuel management accountability. The Quantum Series, with its Piusi MCBox fuel management system supporting up to 120 users, is designed for exactly this environment – tracking individual vehicle usage without ongoing software fees. The lockable cabinet and self-bunded construction meet the containment requirements of AS1940 on open land.

civil

Construction and Civil

Construction sites change frequently, and fuel supply needs to move with them. Polymaster self-bunded tanks sit above ground, require no concrete bund, and can be positioned where access is needed. The plug and play setup means minimal site downtime when the tank arrives – everything is factory-fitted and ready to connect.

Transport and Fleet

For transport depots and fleet operators, the Quantum Series fuel management system eliminates manual dip-stick monitoring and manual reconciliation of fuel usage across drivers and vehicles. Up to 120 user keys, automatic timeout after 10 minutes, and a power control box with emergency stop give you operational control and security.

industrial

Trade and Industrial

For trade businesses needing reliable on-site diesel storage – plant hire, earthmoving, or service fleets – the Ranger Series delivers a straightforward, full-featured setup without the fuel management overhead of the Quantum.

Highest Quality and Standards

Designed, engineered, and manufactured right here in Australia – built for our climate, our standards, and our conditions.

AS1940 Compliant Self-Bunding

The double-wall construction satisfies the self-bunding requirements of AS1940, providing 110% secondary containment in a single unit.

UV Tough Construction

The outer bund tank and cabinet are constructed from UV sun-tough, flame-retardant material – built to withstand the harsh Australian sun for the long term.

Australian Made 

Designed, engineered, and manufactured right here in Australia, built for our climate and our conditions.

5 Year Warranty

Every self-bunded Polymaster diesel tank carries a 5-year manufacturer’s warranty.

WHY CHOOSE POLYMASTER

Australian-Made Self-Bunded Diesel Tanks Built for the Job

Polymaster has been engineering liquid storage solutions for Australian conditions for over 30 years. Our self-bunded diesel range is not a generic import adapted for the local market – these are purpose-built, Australian-made units, manufactured from UV sun tough, flame-retardant material designed to handle the heat, UV exposure, and demanding operational conditions of Australian agriculture, mining, and construction sites.

Every unit is delivered as a plug and play setup. That means the pump, hose, digital level indicator, filter, cabinet, and fittings are all factory-installed – your unit arrives ready to position and commission, not as a kit to be assembled on-site. The double-wall self-bunded construction provides 110% secondary containment in a single unit, meeting the bunding requirements of AS1940 without the cost and time of a separate concrete bund structure.

A poly tank will not rust. When your fuel asset needs to sit in the paddock, at the mine, or on a site for years at a time, that matters.

QUANTUM SERIES - FUEL MANAGEMENT SYSTEM

The Quantum Series - Fuel Management for Fleets

The Quantum Series goes beyond storage and dispensing. It adds the Piusi MCBox fuel management system – a fully integrated solution for tracking diesel consumption across up to 120 users, with no ongoing software fees.

The system ships with 10 user keys and one management key, along with software for desktop reporting. Each user key authorises a transaction; the system records usage by user, preventing unauthorised dispensing and giving you a complete, auditable record of fuel consumption across your fleet or workforce.

The power control box includes an emergency stop and an automatic 10-minute timeout on continual use – protecting your pump and preventing unintended dispensing. The 10-metre retractable hose reel with auto-shutoff trigger nozzle adds reach and safety at the point of delivery.

For mining operations, transport fleets, and any site running multiple vehicles and operators, the Quantum removes the manual tracking overhead and gives you real accountability from day one.

INSTALLATION OVERVIEW

Installing Your Self-Bunded Diesel Fuel Tank

Polymaster self-bunded diesel tanks are delivered as plug and play units – the pump, hose, fittings, and controls are all factory-installed. Installation primarily involves positioning, commissioning the pump, and completing the electrical connection. The following overview covers the key stages. Download the Polymaster Self-Bunded Diesel Tank Installation Guide for full specifications.

Select a firm, level surface capable of bearing the loaded weight of the tank. Observe the required separation distances from buildings, boundaries, and ignition sources as specified in AS1940. Ensure adequate clearance for the fill truck to access the 2-inch Camlock fill point.

The Piusi 240V pump requires a licensed electrician to complete the electrical connection. The power control box (Ranger and Quantum series) includes an emergency stop and auto-timeout. All wiring must be performed by a licensed electrician – do not attempt to connect electrical components yourself.

Once power is connected, prime and commission the pump per the Piusi pump commissioning instructions supplied with the unit. Test flow rate and confirm the auto-shutoff nozzle operates correctly.

Install the Piusi MCBox software on your management computer. Programme the management key and distribute user keys to authorised operators. Test each key to confirm access authorisation. Refer to the Piusi MCBox manual supplied with the unit.

Label the tank with contents (diesel) and hazard class as required by AS1940. Confirm separation distances are met. Retain a copy of the installation guide and warranty documentation.

Polymaster self-bunded diesel tanks must be positioned and commissioned in accordance with AS1940:2017 and the Polymaster Self-Bunded Diesel Tank Installation Guide. All electrical connections must be completed by a licensed electrician. Failure to comply may void the warranty and create a compliance liability.

DIESEL TANK CASE STUDIES

Trusted by Australian Businesses to Deliver These Projects

Polymaster’s self-bunded diesel range is manufactured to the highest quality standards and trusted by operators across agriculture, mining, construction, and transport throughout Australia.

DELIVERY AND DISTRIBUTION

Delivery Across Victoria, South Australia, New South Wales, and Queensland

Preparing Your Site

Truck and trailer clearance required is 19 metres long, 5 metres high, and 3.5 metres wide. Check for low branches or powerlines on your access route and ensure your gate and entrance can accommodate a 19m truck and trailer. A flat, clear area of at least 5 metres by 5 metres is required for unloading. Our logistics team will contact you approximately seven days before delivery to confirm your address and access requirements.

Not Sure Which Series Suits Your Site?

Talk to our team. We will help you match the right self-bunded diesel tank to your operation – whether it is a single farm unit or a fleet-scale Quantum setup for a mining or transport site.

Ag - Customer Service Team Member

FAQs

Frequently Asked Questions

Everything you need to know about Polymaster’s self-bunded diesel fuel tanks, from compliance and sizing through to installation and maintenance.

A self-bunded diesel fuel tank is a tank within a tank. The inner tank stores the diesel; the outer tank acts as a bund, providing secondary containment for 110% of the inner tank’s capacity in the event of a leak or spill. This design satisfies the bunding requirements of AS1940 in a single above-ground unit, eliminating the need to construct a separate concrete or earthen bund on-site. Polymaster’s self-bunded range is manufactured with double poly walls in UV sun tough, flame-retardant material.

Yes. AS1940:2017 is the Australian standard for the storage and handling of flammable and combustible liquids. It permits fire-retardant polyethylene tanks for diesel storage and specifies that bunding must provide secondary containment of 110% of tank capacity. Polymaster’s self-bunded tanks meet this requirement in a single unit. You are still required to observe the separation distances from buildings, boundaries, and ignition sources specified in the standard, and to label the tank with its contents and hazard class. For farm use on open land greater than 2 hectares, AS1940 permits poly diesel tanks up to a maximum of 10,000L.

All three series share the same self-bunded double-wall construction, quality Italian Piusi 240V pump rated to 70LPM, lockable equipment cabinet, digital level indicator, 30-micron water capture filter, and mechanical overfill protection. The Ranger adds a power control box with emergency stop and auto-timeout, digital fluid meter, and high/low level alarms. The Quantum adds everything in the Ranger plus a 10-metre retractable hose reel and the Piusi MCBox fuel management system, which tracks consumption across up to 120 users with no ongoing fees. The Essential is the entry-level configuration; the Quantum is designed for fleet and multi-operator environments.

For most farming operations and smaller construction sites, a 5,000L unit provides a practical balance between capacity and site footprint. A 10,000L unit suits larger operations with higher daily consumption or sites where delivery frequency needs to be minimised. As a rough guide: a harvester consuming 25-30 litres per hour running for 10 hours per day will use around 250-300 litres daily; a 10,000L tank provides approximately 33 days of supply at that rate. Our team can help you work through consumption estimates for your specific situation.

Yes. The Piusi 240V pump requires a 240V power connection, and all electrical wiring must be completed by a licensed electrician. The power control box (Ranger and Quantum series) must also be wired by a licensed electrician. Attempting to complete electrical connections without a licence is a safety hazard and will void the warranty. Beyond the electrical connection, positioning and commissioning the unit can generally be completed without a licensed trades person, following the Polymaster Self-Bunded Diesel Tank Installation Guide.

No. Self-bunded tanks are designed for above-ground use on a firm, level surface – they do not require a concrete pad. The surface needs to be capable of bearing the loaded weight of the tank and level enough to ensure accurate level readings. Gravel, compacted earth, or concrete are all suitable. The key requirement is stability and separation from buildings, boundaries, and ignition sources as specified in AS1940.

The tank is filled via the 2-inch Camlock with ball valve on the top of the unit. A fuel delivery truck connects to this fitting to fill the inner tank. Mechanical overfill protection is standard across all three series. Ensure your site access is clear for the fuel delivery vehicle and that the anti-splash/anti-static top-fill assembly (Essential Series) or equivalent is in place before filling.

The Piusi MCBox system controls access to the pump via individual user keys. Each operator inserts their key to authorise a dispensing transaction; the system records the transaction against that key’s user ID. A management key and desktop software allow the site manager to review consumption data by user. The system ships with 10 user keys and one management key and supports up to 120 users in total. Additional keys can be purchased separately. There are no ongoing software fees.

Polymaster recommends inspecting the unit every 6 months. Check the pump filters and replace as needed. Inspect the hose and nozzle for wear or damage. Check the level gauge and alarms for correct operation. Inspect the bund for any accumulated water and drain if required. Inspect all fittings and seals for signs of wear. For detailed service guidance, refer to Polymaster’s maintenance article (polymaster.com.au/news/how-do-i-service-and-protect-my-diesel-and-adblue-bunded-tank/) or contact our team.

No. Diesel and AdBlue must never be stored in the same tank. Polymaster manufactures a separate self-bunded AdBlue range – the Dieselmaster AdBlue series – specifically engineered for AdBlue storage, with materials compatible with the chemical properties of AdBlue. Using a diesel tank for AdBlue storage will contaminate the AdBlue and damage the tank’s fittings and pump. See the Polymaster self-bunded AdBlue tanks range for the appropriate product.

The Essential Series carries a 5-year manufacturer’s warranty.

Ask a Specialist

Fill in the form below and a specialist will be in touch within 24 hours to discuss your needs and answer any questions.

Ask A Specialist Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*

Download Step File

Lorem ipsum dolor sit amet consectetur. Cursus enim dictum pellentesque vulputate elementum at. Adipiscing ut massa praesent.

Download Step File Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Postcode
Country

Cow Popup