Fire Fighting Pumps and Accessories

The tank holds the water. The pump is what puts it where you need it, and on a bad day that difference matters.

Polymaster fire fighting pumps run from a 2.5HP portable up to a 7HP Yanmar diesel with electric start, all built on Onga pump ends. Alongside them, the hose reels, nozzles and fill kits that complete a unit or upgrade one you already have.

Ag - Customer Service Team Member

FEATURED PUMPS AND ACCESSORIES

The Three Products We’re Asked For Most

Honda pump 5.5

Honda 5.5HP Single Impeller Pump

585 LPM at 60 metres of head, the highest flow in the range. Three outlets, so you can run a hose reel and a hand line at once. The pump that goes in most compact fire units.

Honda Pump 6.5

Honda 6.5HP Twin Impeller Pump

100 metres of head, which is what you want when the water has to go uphill or a long way down a hose. Available with pull or electric start.

FHR_Product Manual Hose Reel (Front)

Hose Reel, 20mm x 36m

Thirty-six metres of hose on a reel, so you can work around a shed or a fence line without moving the vehicle. Fitted as standard on HR model units and available separately.

POLYMASTER FIRE FIGHTING PUMPS AND ACCESSORIES

Browse the range

Every pump uses an Onga (Pentair) pump end. The engine and starter vary, and so does what the pump is built to do.

Code Product
Honda 5.5HP (Single Impeller)B55HHonda 5.5HP (Single Impeller)-
Honda 6.5HP (Twin Impeller)B65HTHonda 6.5HP (Twin Impeller)-
Honda 6.5HP (Twin Impeller / Electric Start)B65HTESHonda 6.5HP (Twin Impeller / Electric Start)-
Dust Suppression NozzleDSN20KDust Suppression Nozzle-
Hose ReelFFHR1Hose Reel-
Hose Reel (manual)FHRHose Reel (manual)-
Honda 5.5HP (Single Impeller)

Honda 5.5HP (Single Impeller)

B55H

Specifications
-
Honda 6.5HP (Twin Impeller)

Honda 6.5HP (Twin Impeller)

B65HT

Specifications
-
Honda 6.5HP (Twin Impeller / Electric Start)

Honda 6.5HP (Twin Impeller / Electric Start)

B65HTES

Specifications
-
Dust Suppression Nozzle

Dust Suppression Nozzle

DSN20K

Specifications
-
Hose Reel

Hose Reel

FFHR1

Specifications
-
Hose Reel (manual)

Hose Reel (manual)

FHR

Specifications
-

Not sure which pump suits your setup?

Tell us the tank, the hose length and what you’re trying to reach, and we’ll work it out. Call 1800 062 064.

Flow or head, and why it matters

Two numbers decide which pump suits your job, and they pull in opposite directions.

Flow, measured in litres per minute, is how much water the pump moves. High flow suits knocking down a grass fire fast, or filling a trough or another tank. 

Head, measured in metres, is how hard the pump pushes. High head suits getting water uphill, out to the far end of a long hose, or through a hose reel that eats pressure. 

That’s why the 5.5HP single impeller moves 585 LPM at 60 metres of head, while the 6.5HP twin impeller moves less water at 373 LPM but pushes it to 100 metres. The twin impeller is not a bigger version of the single. It is a different tool. 

The 5.5HP single impeller. Highest flow in the range, three outlets, and enough head for anything within reach of a 36 metre reel on flat ground.

The 6.5HP twin impeller. 100 metres of head covers a rise, a long line, or a reel that would starve a lower pressure pump.

The 2.5HP Mini Blaze. One outlet, 133 LPM, and light enough to lift on and off without help.

The 7HP Yanmar diesel with electric start. Same 100 metres of head as the twin impeller, more flow at 450 LPM, and it runs on the same fuel as the vehicle carrying it.

Not sure which pump you need?

Tell us the tank, the hose you’re running and what you need to reach. We’ll work out which pump does the job.

Plumbing - Customer Service Team Member

FAQs

Fire fighting pump and accessory questions

It depends on whether you need flow or pressure. The 5.5HP single impeller gives the highest flow at 585 LPM, which suits knocking a fire down fast on flat ground. The 6.5HP twin impeller gives 100 metres of head, which suits hills, long hose runs and hose reels. Section above sets out the full comparison.

Because they’re built for different jobs. A single impeller pump moves more volume at lower pressure. A twin impeller pump moves less volume but pushes it much harder. The 6.5HP is not a bigger 5.5HP, it’s a different tool.

Onga, which is Pentair, across the whole range. The engines vary: Loncin on the Mini Blaze, Honda on the 5.5HP and both 6.5HP models, and Yanmar on the 7HP diesel.

Yes, on the 6.5HP twin impeller and the 7HP diesel. The 2.5HP and 5.5HP are pull start.

The Mini Blaze has one 25mm outlet. Every other pump in the range has three, two at 25mm and one at 40mm, so you can run a hose reel and a hand line at the same time.

Both reels carry 20mm hose at 36 metres. They differ in form rather than capacity, so which one suits depends on how it’s being mounted.

It converts a fire fighting unit into a dust suppression setup, which is useful on unsealed roads, work sites and yards. The DSN20K is an option on skid mounted and trailer mounted units.

It lets you fill the tank from the bottom rather than through the top lid, which is faster and means no climbing. It suits the 5.5HP compact fire units.

Yes. These pumps and accessories are supplied as part of complete units and as standalone items. Tell us the tank you’re running and we’ll confirm what suits.

Ask a Specialist

Fill in the form below and a specialist will be in touch within 24 hours to discuss your needs and answer any questions.

Ask A Specialist Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*

Download Step File

Lorem ipsum dolor sit amet consectetur. Cursus enim dictum pellentesque vulputate elementum at. Adipiscing ut massa praesent.

Download Step File Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Postcode
Country

Cow Popup