Home Agriculture Def Tanks for AdBlue® Self-Bunded Def Tanks for AdBlue®
Self-Bunded DEF Tanks for AdBlue®
Every SCR-equipped vehicle in your fleet needs AdBlue® to operate. Storing and dispensing it correctly is not optional – contamination from moisture, heat, or the wrong materials will degrade the AdBlue® and damage the SCR system it is meant to protect.
Polymaster’s Self-Bunded DEF Tanks for AdBlue® are purpose-built for bulk AdBlue® storage and dispensing. Australian-made, plug and play, and delivered ready to commission – double poly walls provide built-in 110% secondary containment, protecting your AdBlue® and your site from spills.
POLYMASTER SELF-BUNDED DEF TANK SOLUTIONS FOR ADBLUE®
Browse Our Range of Self-Bunded DEF Tanks for AdBlue®
Three series across five capacities. All share the same self-bunded double-wall construction, 110% bund capacity, and plug-and-play setup. The difference is in the power source, pump type, and management capability.
| Code | Product | Capacity (L) | ||
|---|---|---|---|---|
| BMDS2300 - 10000D | Self-Bunded DEF Tank 240V – Depot Range | 2,300 / 3,300 / 5,000 / 7,000 / 10,000 | 10,000L Drawing Download Data Sheet | |
| BMDS2300 - 10000D-12V | Self-Bunded DEF Tank 12V – Depot Range | 2,300 / 3,300 / 5,000 / 7,000 / 10,000 | 10,000L Drawing Download Data Sheet | |
| BMDS2300 - 10000S | Self-Bunded DEF Tank 240V – Submersible Range | 2,300 / 3,300 / 5,000 / 7,000 / 10,000 | 10,000L Drawing Download Data Sheet | |
| BMDS2300 - 10000T | Self-Bunded DEF Tank 240V – Terminal Range | 2,300 / 3,300 / 5,000 / 7,000 / 10,000 | 10,000L Drawing Download Data Sheet |
Self-Bunded DEF Tank 240V – Depot Range
BMDS2300 - 10000D
Self-Bunded DEF Tank 12V – Depot Range
BMDS2300 - 10000D-12V
Self-Bunded DEF Tank 240V – Submersible Range
BMDS2300 - 10000S
Self-Bunded DEF Tank 240V – Terminal Range
BMDS2300 - 10000T
Not sure which series or capacity suits your fleet operation?
Our team can help. Call us on 1800 062 064 or use the quote tool above.
WHICH SERIES SUITS YOUR OPERATION?
Depot, Terminal, or Submersible - Choosing the Right Series
All three series share the same self-bunded double-wall construction, 110% bund capacity, standard safety inclusions, and plug-and-play setup. The difference is in power source, pump type, hose configuration, and whether you need fuel management accountability.
Depot Series - Simple, Reliable Fleet Dispensing
Terminal Series - Managed Dispensing with User Accountability
The Terminal series adds the 120-user fuel management system to the Depot configuration. Individual users require a key to activate the pump; the system logs each dispensing transaction against the user, giving you a complete, auditable record of AdBlue® consumption across your fleet. An 8-metre retractable hose reel replaces the 5-metre hose.
Ideal for: larger transport fleets, mining operations, council depots, and any site where AdBlue® consumption needs to be tracked by vehicle or operator. Suited to multi-user environments where accountability and waste prevention are a priority.
Submersible Series - Storage for Remote Bowser Connection
The Submersible series replaces the external Piusi pump with a Calpeda submersible pump (standard) or Franklin submersible pump (option) mounted inside the tank. The discharge terminates within the cabinet at a 25mm (1-inch) outlet, which connects to a remote bowser or dispensing point. This configuration is specifically suited to service stations, public AdBlue® dispensing points, and any site where the storage unit needs to be located away from the dispensing point.
Ideal for: service station forecourts, roadside AdBlue® dispensing points, and any installation where the pump and storage are separated from the point of dispensing.
Highest Quality and Standards
Every Polymaster DEF tank bunded station for AdBlue® is Australian-made, plug and play ready, and engineered to protect your AdBlue® from contamination, temperature damage, and spills.
ISO 9001 Quality Management
Polymaster holds ISO 9001 certification – the international standard for quality management systems.
AS/NZS 4766 Certified
Independently certified to AS/NZS 4766:2020 for polyethylene storage tanks.
Australian Made
Designed, engineered, and manufactured right here in Australia, built for our climate and our conditions.
5 Year Warranty
Every Polymaster DEF tank bunded station for AdBlue® carries a 5-year manufacturer’s warranty on the tank.
WHY CHOOSE POLYMASTER
Australian-Made Self-Bunded DEF Tanks for AdBlue®, Built to Protect Your Fleet
Why Choose Polymaster Self-Bunded DEF Tanks for AdBlue®
Self-Bunded - Tank Within a Tank
Double poly walls with 110% bund capacity built in. No separate bund structure required. Any spill or leak is contained within the unit – protecting your site, your AdBlue®, and your compliance obligations.
Stainless Steel Drybreak Fill Fitting
The 50mm (2-inch) stainless steel drybreak fill fitting prevents contamination during the fill process – a critical protection point given AdBlue®’s sensitivity to impurities.
Plug and Play - Ready to Commission
Every unit arrives factory-fitted: pump, digital tank volume measurement, overfill protection, alarms, cabinet, hose, and nozzle all installed. Commission on-site, not in a workshop.
Optional Fuel Management - 120 Users
The Terminal series adds a 120-user fuel management system as standard – the same accountability capability as Polymaster’s diesel Quantum series, applied to AdBlue® operations.
STANDARD INCLUSIONS ACROSS THE RANGE
What Comes With Every Polymaster DEF Tank Bunded Station for AdBlue®
Every unit in the BMDS range ships with a comprehensive set of standard inclusions:
- The tank and bund: self-bunded double poly wall construction with 110% bund capacity, mechanical overfill protection, earth rod, stainless steel drybreak fill fitting (50mm, 2-inch), and digital tank volume measurement.
- The control and safety equipment: power control panel with emergency stop, auto timeout (10 minutes), high and low level audible alarms, bund alarm, lockable cabinet.
- The dispensing equipment: Piusi or Calpeda pump (depending on series), hose with auto-shutoff nozzle and holster, digital flow meter (Depot and Terminal series), and digital or pulse meter (series dependent).
- Optional add-ons available across the range include an ATG probe tube, tank lifting lugs, and an 8-metre retractable hose reel (standard on Terminal, optional on Depot).
DELIVERY AND DISTRIBUTION
Delivery Across Victoria, South Australia, New South Wales, and Queensland
Preparing Your Site
Truck and trailer clearance required is 19 metres long, 5 metres high, and 3.5 metres wide. Check for low branches or powerlines on your access route and ensure your gate and entrance can accommodate a 19m truck and trailer. A flat, clear area of at least 5 metres by 5 metres is required for unloading. Our logistics team will contact you approximately seven days before delivery to confirm your address and access requirements.
INSTALLATION OVERVIEW
Installing Your DEF Tank Bunded Station for AdBlue®
Polymaster DEF tank bunded stations for AdBlue® are plug-and-play units – pump, fittings, controls, and cabinet all factory-installed. Installation involves site preparation, positioning, electrical connection, and commissioning. Download the Polymaster AdBlue® Bunded Station Installation Guide for full specifications.
Step 1 - Site Preparation and Positioning
Select a firm, level surface capable of bearing the loaded weight of the unit. Position to allow access for the AdBlue® delivery vehicle to reach the stainless steel drybreak fill fitting. Ensure adequate clearance around the cabinet for maintenance access.
Step 2 - Electrical Connection
The pump and control panel require a licensed electrician to complete the electrical connection. The Depot 12V option connects to a 12V vehicle battery; the 240V Depot, Terminal, and Submersible configurations require a mains electrical connection. All wiring must be completed by a licensed electrician.
Step 3 - Pump Commissioning and Testing
Commission the pump per the Piusi or Calpeda commissioning instructions supplied with the unit. Test flow rate, auto-shutoff nozzle, and overfill protection. Test the high/low level alarms and bund alarm for correct operation.
Step 4 - Fuel Management Setup (Terminal Series Only)
Program the management key and distribute user keys to authorised operators. Test each key for access authorisation. Review the digital display and confirm transaction logging is active before commissioning.
Step 5 - AdBlue® Delivery and First Fill
Arrange AdBlue® delivery via an approved AdBlue® supplier using the drybreak fill fitting. Do not allow any non-AdBlue® material, water, or incompatible liquids to enter the tank. Confirm the digital tank volume reading after the first fill.
Polymaster DEF tank bunded stations for AdBlue® must be installed in accordance with the Polymaster AdBlue® Bunded Station Installation Guide. All electrical connections must be completed by a licensed electrician. AdBlue® is sensitive to contamination – only fill from an approved AdBlue® supply source using the drybreak fitting provided.
DEF TANK FOR ADBLUE® CASE STUDIES
Trusted by Australian Businesses to Deliver These Projects
Polymaster’s self-bunded DEF tanks for AdBlue® are Australian-made and trusted by transport operators, fleet managers, and mining operations across Australia.
“Great quality tank and really easy to use. The self-bunded design gives us peace of mind and the setup has been hassle-free.”
“Polymaster’s DEF AdBlue tank has been a great addition to our site. Reliable, well-built and simple to operate.”
Not Sure Which Series or Capacity Suits Your Fleet?
Talk to our team. We will help you match the right self-bunded DEF tank for AdBlue® to your fleet size, power supply, and dispensing requirements.
MORE DEF TANK SOLUTIONS FOR ADBLUE® FROM POLYMASTER
Explore Our Full Range of DEF Tank Solutions for AdBlue®
Our self-bunded bulk storage range is one part of Polymaster’s DEF tank offer for AdBlue®. If you need portable ute packs, pumps and accessories, or parts and replacements, we have the full range.
Portable DEF Tank Pods for AdBlue®
Compact, portable DEF tank pods for AdBlue® dispensing, for on-the-go top-up of SCR-equipped vehicles in the field.
View Range
Pumps, Parts and Accessories for AdBlue®
Replacement Piusi pumps, nozzles, hose reels, and AdBlue®-compatible accessories for your bulk storage setup.
View Range
Self-Bunded Diesel Fuel Tanks
If you need diesel bulk storage alongside AdBlue®, Polymaster’s Essential, Ranger, and Quantum self-bunded diesel range is the direct equivalent for fuel.
View Range
FAQs
Frequently Asked Questions
Everything you need to know about Polymaster’s self-bunded diesel fuel tanks, from compliance and sizing through to installation and maintenance.
What is a self-bunded DEF tank for AdBlue®?
A self-bunded Def tank for AdBlue® is a double-walled storage unit – an inner tank holds the AdBlue®, and the outer wall forms a bund providing 110% secondary containment in the event of a leak or spill. Polymaster’s BMDS range combines this self-bunded construction with a factory-installed pump, controls, alarms, and dispensing equipment in a single plug-and-play unit.
Why does AdBlue® need special storage?
AdBlue® is a urea solution that degrades when exposed to heat (above approximately 25°C), UV, moisture, or contact with incompatible materials such as copper, zinc, or carbon steel. Contaminated AdBlue® will not perform correctly in an SCR system and can damage the catalyst. Purpose-built poly storage with stainless steel fittings and a sealed, lockable cabinet protects the AdBlue® from these degradation risks.
What is the difference between the Depot and Terminal series?
Both series use the same self-bunded tank construction and Piusi AdBlue® pump. The Depot series is a straightforward dispensing setup – pump, 5m hose, digital flow meter, alarms, and lockable cabinet. The Terminal series adds a 120-user fuel management system with individual user keys, an 8-metre retractable hose reel, and a pulse meter for managed dispensing accountability. Choose Depot for simpler fleet operations; choose Terminal where you need to track AdBlue® consumption by operator or vehicle.
How often should AdBlue® bulk storage be maintained?
Polymaster recommends inspecting the unit every 6 months. Check the pump filters, hose, and nozzle for wear or contamination. Test the alarms and overfill protection. Inspect the bund for accumulated liquid and drain as required. Clean the fill point and drybreak fitting. Flush the system if the AdBlue® has been stored for an extended period. For detailed maintenance guidance, refer to the Polymaster AdBlue® Bunded Station Installation Guide.
What is the Submersible series used for?
The Submersible series replaces the external Piusi pump with a Calpeda submersible pump mounted inside the tank, with the discharge terminating at a cabinet outlet. This configuration is designed for remote bowser connections – the storage unit sits in one location and the dispensing bowser is positioned separately, connected via pipework. It is particularly suited to service station forecourts and public AdBlue® dispensing points.
Can I add a fuel management system to a Depot unit?
The 120-user fuel management system is a standard inclusion on the Terminal series and cannot be added to a Depot unit as a factory option. If you need fuel management, specify the Terminal series. Contact Polymaster to discuss your requirements if you need a configuration not covered by the standard range.
What sizes are available?
Polymaster’s self-bunded Def tanks for AdBlue® bunded stations are available in 2,300L, 3,300L, 5,000L, 7,000L, and 10,000L across the Depot, Terminal, and Submersible series. Not every series is available in every size – see the product table above for the full range.





















