Home Agriculture Diesel Tanks & Fuel Storage Single Walled Diesel Tanks
Single-Walled Diesel Fuel Tanks
Polymaster’s single-walled diesel fuel tanks give you straightforward above-ground diesel storage for sites with an existing bund, or room to build one.
Available in 5,000L, 7,000L and 10,000L, as tank only or tank plus dispenser. Diesel-grade polyethylene, UV stabilised for Australian conditions, certified to AS/NZS 4766:2020, 5-year tank warranty.
POLYMASTER SINGLE-WALLED DIESEL FUEL TANK SOLUTIONS
Browse Our Range of Single-Walled Diesel Fuel Tanks
Two configurations across three capacities. The tank-only option suits sites with an existing bund. The tank plus dispenser adds a plug-and-play Italian pump, lockable cabinet, and dispensing kit for sites that need on-site fuelling capability.
| Code | Product | Capacity (L) | ||
|---|---|---|---|---|
| DSW5000 - 10000+DK-240V | Diesel Storage Tank with Dispenser Kit – 240V | 5,000 / 7,000 / 10,000L | ||
| DSW5000 - 10000+DK-12V | Diesel Storage Tank with Dispenser Kit – 12V | 5,000 / 7,000 / 10,000 | ||
| DSW5000 - 10000 | Diesel Storage Tank | 5,000 / 7,000 / 10,000 |
Diesel Storage Tank with Dispenser Kit – 240V
DSW5000 - 10000+DK-240V
Diesel Storage Tank with Dispenser Kit – 12V
DSW5000 - 10000+DK-12V
Diesel Storage Tank
DSW5000 - 10000
Not sure whether you need tank only or tank plus dispenser?
Our team can help you work through what your site needs. Call us on 1800 062 064 or use the quote tool above.
WHICH CONFIGURATION DO YOU NEED?
Tank Only or Tank Plus Dispenser - Choosing the Right Configuration
Single-walled diesel tanks require a separately installed bund structure to meet the secondary containment requirements of AS1940. Once that bunding is in place, the choice comes down to how you want to dispense.
Tank Only
The tank-only option is suited to sites where dispensing infrastructure is already in place, or where you are adding storage capacity to an existing setup. These units provide above-ground diesel storage with standard fittings – level gauge, camlock fill point, brass outlet with ball valve, overfill protection, and earthing rod. Dispensing pump, hose, and cabinet are not included and must be sourced and installed separately.
Typical applications: adding bulk storage to a site with an existing pump and dispenser, sites where the dispensing setup is centralised, or situations where a custom pump configuration is required.
Tank + Dispenser
The tank plus dispenser configuration adds a quality Italian pump, lockable pump cabinet, and plug-and-play dispensing setup to the same tank. Available in 240V and 12V. This is the complete above-ground dispensing solution for sites that need storage and fuelling capability in one unit.
Typical applications: new installations on farm, construction, or mining sites where no dispensing infrastructure exists, fleet operations that need a standalone refuelling point, or any site where a plug-and-play setup minimises installation time and cost.
The Bunding Requirement
Unlike Polymaster’s self-bunded range, single-walled tanks do not include built-in secondary containment. Under AS1940:2017, above-ground diesel storage requires a bund capable of containing 110% of the tank’s capacity. This can be a concrete bund, earthen bund, or proprietary bund system – your installer or site planner will advise on what is appropriate for your site. If you need a self-contained solution that removes the bunding requirement, see Polymaster’s self-bunded diesel fuel tanks.
Highest Quality and Standards
Every Polymaster poly septic tank is built to last and independently certified, so you can have complete confidence in what you are putting in the ground.
Australian Made
Designed, engineered, and manufactured right here in Australia, built for our climate and our conditions.
UV Stabilised Polyethylene
Built from diesel-grade Hexathene material with UV stabilisation for longer service life in Australia’s harsh sun. A poly tank will not rust.
5 Year Warranty
Every single-walled Polymaster diesel tank carries a 5-year manufacturer’s warranty.
Independently Certified
Certified to AS/NZS 4766:2006 for polyethylene storage tanks.
WHY CHOOSE POLYMASTER
Australian-Made Diesel Storage Tanks Built for the Field
Polymaster’s single-walled diesel tanks are built in Australia using diesel-grade Hexathene polyethylene – a material specifically engineered for fuel storage, UV stabilised to handle the demands of Australian conditions, and certified to AS/NZS 4766.
A poly tank will not rust, corrode, or degrade the way a steel tank does when left in the paddock or on a site. The tanks are purpose-built for above-ground diesel storage across farming, civil, construction, fleet, and mining applications, and are available through more than 1,600 agricultural and trade stores across Victoria, South Australia, New South Wales, and Queensland.
The tank plus dispenser range adds an Italian pump, lockable cabinet, and plug-and-play dispensing setup, giving you a complete above-ground fuelling station ready to commission once your bund is in place.
Why Choose Polymaster Single-Walled Diesel Fuel Tanks
Polymaster’s round tank range covers more applications than any other single product line in our catalogue. Here is how to match the right tank to your situation.
Diesel-Grade Hexathene Construction
Not all poly is the same. Polymaster uses diesel-grade Hexathene polyethylene – the right material for fuel storage, with the UV stabilisation needed for long-term performance in Australian conditions.
AS/NZS 4766 Certified, 5-Year Warranty
Every unit is tested and certified to Australian Standard AS/NZS 4766 and backed by a 5-year manufacturer’s warranty. That is the quality assurance that matters when your fuel supply is on the line.
Standard Safety Fittings as Standard
Clock type level gauge, mechanical overfill protection, earthing rod, breathing vents, and a 2-inch camlock fill point are standard across the range – not optional extras.
Tank Plus Dispenser Available in 240V and 12V
The dispenser configuration suits both mains-powered sites and off-grid locations running 12V systems. Italian pump quality as standard – no substitutions.
AS1940 BUNDING COMPLIANCE
Understanding the Bunding Requirement for Single-Walled Diesel Tanks
Australian Standard AS1940:2017 governs the storage and handling of flammable and combustible liquids, including diesel. For above-ground storage tanks, the standard requires secondary containment – a bund – capable of containing 110% of the tank’s capacity in the event of a spill or leak.
Single-walled tanks do not include built-in secondary containment. You will need to install an approved bund structure before or alongside your tank. Options include a concrete bund, an earthen bund, or a modular proprietary bund system. Your installer, site planner, or local council will advise on what is appropriate for your specific site and storage volume.
Once the bund is in place, the tank plus dispenser range (DSW+DK series) is explicitly designed to comply with AS1940:2017 when installed within an approved bund. The tank only range (DSW series) requires the same bunding but gives you flexibility to configure your own dispensing setup.
If your site cannot accommodate a separate bund structure, or if you want self-contained secondary containment in a single above-ground unit, Polymaster’s self-bunded diesel fuel tank range satisfies the bunding requirement without any additional construction.
"We wanted a straightforward diesel storage solution that would handle the conditions on our property. The Polymaster tank is robust, practical and has done exactly what we needed."
"Having our own diesel storage on-site has made life much easier. The Polymaster tank is well designed, easy to access and has been a reliable solution for us."
INSTALLATION OVERVIEW
Installing Your Single-Walled Diesel Fuel Tank
Installation requires a bund to be in place before or at the time the tank is positioned. The following overview covers the key stages for both the tank-only and tank-plus-dispenser configurations. Download the Polymaster Diesel Bulk Storage Tank Installation Guide for full specifications.
Step 1 - Bund Preparation
Install or confirm your bund structure before positioning the tank. The bund must be capable of containing 110% of the tank’s capacity in accordance with AS1940:2017. Concrete, earthen, and proprietary modular bunds are all acceptable. Your installer or site planner will advise on the appropriate bund type for your site.
Step 2 - Site Selection and Tank Positioning
Select a firm, level surface within the bund. Observe the required separation distances from buildings, boundaries, and ignition sources as specified in AS1940. Ensure adequate clearance for the fill truck to access the camlock fill point.
Step 3 - Plumbing the Outlet and Fittings
Connect the 2-inch brass outlet with ball valve to your dispensing line or pump. Ensure all connections are tight and leak-free. Install the earthing rod in accordance with the installation guide.
Step 4 - Electrical Connection (Tank + Dispenser only)
The Italian pump in the tank plus dispenser configuration requires a licensed electrician to complete the electrical connection. The 240V and 12V pump options have different connection requirements – confirm your site’s power supply before ordering. All electrical wiring must be completed by a licensed electrician.
Step 5 - Commissioning and Labelling
Test the level gauge, overfill protection, and all fittings before the first fill. Label the tank with contents (diesel) and hazard class as required by AS1940. Retain a copy of the installation guide and warranty documentation on-site.
Polymaster single-walled diesel tanks must be installed within an approved bund structure and in accordance with AS1940:2017 and the Polymaster Diesel Bulk Storage Tank Installation Guide. All electrical connections on the Tank + Dispenser configuration must be completed by a licensed electrician.
DELIVERY AND DISTRIBUTION
Delivery Across Victoria, South Australia, New South Wales, and Queensland
Preparing Your Site
Truck and trailer clearance required is 19 metres long, 5 metres high, and 3.5 metres wide. Check for low branches or powerlines on your access route and ensure your gate and entrance can accommodate a 19m truck and trailer. A flat, clear area of at least 5 metres by 5 metres is required for unloading. Our logistics team will contact you approximately seven days before delivery to confirm your address and access requirements.
Not Sure Which Tank or Configuration Suits Your Site?
Talk to our team. We will help you match the right diesel storage solution to your site, whether that is a tank only for an existing bund setup or a complete tank plus dispenser for a new installation.
MORE DIESEL TANK SOLUTIONS FROM POLYMASTER
Explore Our Full Range of Diesel Tank Solutions
Our single-walled range suits sites with an existing bund or the space to install one. If you need self-contained secondary containment, portable on-the-go fuelling, or a trailer-mounted unit, we have you covered.
Self-Bunded Diesel Fuel Tanks
No separate bund required. Polymaster’s Essential, Ranger, and Quantum series provide self-contained double-wall secondary containment in 5,000L and 10,000L capacities – the complete solution for sites where a separate bund is not practical.
View Range
Portable Diesel Fuel Tank Ute Pods
Compact diesel cube and ute pack units from 100L to 600L for on-the-go refuelling of machinery, vehicles, and equipment in the field.
View Range
Diesel Transfer Tanks
Transfer diesel between vehicles, equipment, and bulk storage. Available in a range of capacities for agricultural, construction, and mining applications.
View Range
FAQs
Frequently Asked Questions
Everything you need to know about Polymaster’s single-walled diesel storage tanks, from compliance and bunding through to sizing and maintenance.
What is a single-walled diesel storage tank?
A single-walled diesel storage tank is an above-ground, single-skin poly tank for bulk diesel storage. Unlike a self-bunded tank, it does not include built-in secondary containment – you must install a separate bund structure to meet the requirements of AS1940:2017. In exchange for that additional site requirement, single-walled tanks are simpler in construction, available at a lower price point, and give you full flexibility over how your dispensing and bunding are configured.
Do I need a bund for a single-walled diesel tank?
Yes. Australian Standard AS1940:2017 requires secondary containment – a bund capable of holding 110% of the tank’s capacity – for above-ground diesel storage. Single-walled tanks do not include built-in bunding, so you must install an approved bund structure. If your site cannot accommodate a separate bund, Polymaster’s self-bunded diesel fuel tanks provide the secondary containment within the tank unit itself, meeting the AS1940 requirement without any additional construction.
What is the difference between the tank-only and tank plus dispenser options?
The tank only (DSW series) provides the storage vessel with standard safety fittings – level gauge, camlock fill point, brass outlet, overfill protection, and earthing rod. The pump and dispensing setup must be sourced separately. The tank plus dispenser (DSW+DK series) adds a quality Italian pump (available in 240V or 12V), lockable pump cabinet, and plug-and-play dispensing configuration. Both configurations are otherwise identical in tank construction, certification, and warranty.
What size single-walled diesel tank do I need?
For smaller farming operations and low-to-medium consumption sites, the 5,000L model is a practical starting point. The 7,000L suits medium-scale operations, where the 5,000L would require more frequent delivery, and the 10,000L footprint is not justified. The 10,000L is suited to larger farms, construction sites, and fleet operations with higher daily consumption or less frequent delivery access. As a guide: a 5,000L tank at 20% daily drawdown lasts approximately 5 days; a 10,000L tank at the same rate lasts approximately 10 days. Our team can help you size correctly based on your actual consumption.
What is the difference between a single-walled diesel tank and a self-bunded diesel tank?
A single-walled tank is a single-skin vessel requiring a separately installed external bund to meet AS1940 secondary containment requirements. A self-bunded tank is a tank within a tank – the outer wall acts as the bund, providing 110% secondary containment in a single above-ground unit without additional construction. Self-bunded tanks are the more common choice for new installations where a bund is not already in place, as they remove the need for a separate concrete or earthen bund structure. Single-walled tanks suit sites where a bund already exists or where a custom bunding arrangement is planned.
Are Polymaster single-walled diesel tanks compliant with AS1940?
The tank units themselves are manufactured from diesel-grade polyethylene and certified to AS/NZS 4766, which is the Australian Standard for polyethylene storage tanks. The tank plus dispenser range (DSW+DK series) is designed to comply with AS1940:2017 when installed within an approved bund. The tank only range (DSW series) similarly requires an approved bund to meet AS1940 secondary containment requirements. Compliance depends on the bund installation as well as the tank – the tank alone does not satisfy AS1940 without the bund in place.
Can I get the tank plus dispenser in 12V?
Yes. The tank plus dispenser configuration is available in both 240V and 12V pump options. The 12V option suits off-grid sites, remote locations, and situations where a 240V mains connection is not available or practical. Confirm the voltage requirement when placing your order.
What maintenance does a single-walled diesel tank need?
Polymaster recommends inspecting the unit every 6 months. Check the level gauge for accurate readings. Inspect all fittings, the camlock, and the ball valve for wear or leaks. Check the mechanical overfill protection for correct operation. Inspect the bund for accumulated water and pump out if required. For the tank plus dispenser configuration, inspect the pump filters, hose, and nozzle, and replace as needed. For full maintenance guidance, refer to Polymaster’s service article (polymaster.com.au/news/how-do-i-service-and-protect-my-diesel-and-adblue-bunded-tank/) or contact our team.