Search

Aluminium Chlorohydrate Storage

Aluminium Chlorohydrate, with the chemical formula Al2Cl(OH)5, is a reactive, corrosive coagulant used in water treatment and clean-in-place systems. Polymaster supplies storage and dosing solutions engineered for its specific handling and containment requirements.

OVERVIEW

What is Aluminium Chlorohydrate?

Aluminium Chlorohydrate is a chemical compound with the formula name Al2Cl(OH)5. It is commonly used as an antiperspirant and as a coagulant in water purification processes. At Polymaster, we offer supply tanks for this chemical to be used in various industrial applications.

Aluminium26.98Al13
Chlorine35.45Cl17
Oxygen16.00O8
Hydrogen1.008H1

What material is compatible with Aluminium Chlorohydrate storage?

Polyethylene (PE) is a versatile polymer, but not all PE grades are suitable for chemical storage. “Hexene grade” PE offers enhanced strength and durability.

At Polymaster, we ensure the right PE grade for storing various chemicals, including aluminium chlorohydrate. Our unique PE blends are tested for compatibility with over 2,000 chemicals, ensuring a 25-year design life. All our PEs are UV stabilised for outdoor use.

Polymaster’s ‘Hexene Grade’ PE provides superior chemical resistance and is fully compatible with chemicals requiring higher durability, such as aluminium chlorohydrate. For more details, visit our blog on hexene grade PE and download our Chemical Compatibility Chart

CHEMICAL DOSING SOLUTIONS

Chemical Dosing Solutions

DOSE-DT-DS-15mm-110L

Pre-engineered Dosing Systems

Our pre-engineered dosing systems are designed for precise and efficient dosing of Aluminium Chlorohydrate. These systems are pre-engineered to offer a dosing range which is off-the-shelf and suitable across a wide range of industries. To configure a pre-engineered dosing system suitable for your application, this range offers:

Key Features:
  • Pump Arrangements: Duty or Duty/Standby pump arrangements.
  • Pump Options: 7.5 LPH @ 16 bar up to 200 LPH @ 4 bar – Grundfos DDA Dosing
  • Pumps.
    Pipework and Valves: +GF+ sch80 pipework and valves.
  • Cables and Junction Box: Control Cables and Junction Box.
  • Mounting: These dosing systems are typically mounted inside the Double Door Cabinet and can be integrated to the side of a storage tank or standalone.
  • Documentation: Detailed drawings, datasheets and step files available for these systems.

View Product

Dosing System for Sulphuric Acid

Custom Dosing Systems

Our custom dosing systems are tailored to meet the unique requirements of your specific applications. Polymaster builds custom dosing systems to match client-supplied P&ID’s and we follow the end-users’ specifications, such as a Water Utilities technical specification.

Key Features:
  • Customised Systems: Systems built to your specifications.
  • Precision Dosing: Advanced pumps and controls for accurate chemical delivery.
  • Integration: Seamless integration with your current processes and systems.
  • Safety and Compliance: Designed to meet all relevant standards and end-user specifications.
  • Large Systems: We can build large systems for large-scale applications.

View Product

CHEMICAL SOLUTIONS

Tanks for Aluminium Chlorohydrate Storage

Polymaster’s Self-Bunded range is the ultimate storage solution for Aluminium Chlorohydrate.

This range incorporates the bund with the storage tank, providing a bund capacity of 110% of the internal storage tank. In the unlikely event of a leak, this design prevents chemicals from coming into contact with the environment and personnel.

Polymaster’s chemical tanks are not rainwater tanks and follow strict QA processes, such as hydro testing each tank to ensure they are 100% leak-proof.

110L Chemical Dosing Skid

The 110ltr Dosing Skid is designed for small or remote treatment plants. This unit is setup inside the Polymaster the Double Door Cabinet, making it portable and versatile for different applications.

220L Chemical Dosing Skid

The 220L Dosing Skid offers extra capacity over the 110L unit while retaining the same compact, easy-to-manage footprint. It’s suited to applications with slightly higher dosing demand, without the space or handling requirements of a full-scale storage tank.

Enclosed IBC Bund

All Weather Polyethylene IBC Storage & Dispensing.

Polymaster’s unique Enclosed IBC Bund solves many of the problems associated with IBC storage and chemical/fluid decanting in a weather-resistant, purpose-built enclosure.

1,500L Bunded Chemical Tank

Polymaster’s smallest self-bunded tank, built for sites with tighter footprints or lower-volume chemical use. At 1170mm diameter it’s the most compact in the range, still delivering a fully engineered tank-within-a-tank design with 110% bund capacity, a 25-year design life, and compatibility across 1,965+ chemicals.

2,300L Bunded Chemical Tank

A step up from the 1,500L, the 2,300L self-bunded tank is the first size in the range offered with a double-door cabinet option, giving room to house dosing equipment alongside storage. Same 110% bund capacity and 25-year design life, sized for operations that need a bit more headroom without going bulk.

3,300L Bunded Chemical Tank

The 3,300L sits comfortably in the mid-range for self-bunded storage, still light enough to be despatched on a pallet and unloaded by forklift or crane with spreader bar. It combines the same tank-within-a-tank containment and 25-year design life as the rest of the range, in a footprint that suits growing operations.

5,000L Bunded Chemical Tank

At 2200mm diameter, the 5,000L strikes a balance between capacity and handling ease — still within the pallet/forklift-friendly size bracket, but with meaningfully more storage than the smaller tanks. Fully self-bunded to 110% capacity, it’s a common choice where moderate chemical volumes need dependable, low-fuss containment.

10,000L Bunded Chemical Tank

The 10,000L is the largest self-bunded tank still handled via pallet, forklift, or crane with spreader bar — the practical ceiling before larger units require lifting-plan-specified equipment. It offers substantially more storage while keeping site logistics simple, backed by the same 110% bund capacity and 25-year design life.

13,000L Bunded Chemical Tank

Moving into the range’s larger tanks, the 13,000L is the first size requiring a dedicated lifting plan for installation, and the first offered in a 1.75 SG rating alongside the standard 1.5 and 2 SG options — giving more flexibility for denser chemicals at higher-volume sites.

21,000L Bunded Chemical Tank

Built for high-volume chemical storage, the 21,000L offers the same 1.5, 1.75 and 2 SG options as the 13,000L in a significantly larger footprint (3570mm diameter). Installation follows the 13KL–30KL lifting plan, reflecting the scale of equipment needed to safely place a tank this size.

30,000L Bunded Chemical Tank

The largest tank in Polymaster’s self-bunded range, the 30,000L is built for sites with substantial bulk chemical storage needs. At 3880mm diameter, it carries the same engineering standards as every size below it — 110% bund capacity, 25-year design life — scaled up for maximum single-tank capacity.

HIGHEST QUALITY, CERTIFIED PRODUCTS

Our Tanks are manufactured to the highest Quality & Standards

Quality Assurance

Polymaster is certified for the international standard for quality management ISO9001

Food Grade

Food-grade polyethylene, certified to AS/NZS4020, the Australian standard for drinking water

Product Certification

Manufactured to AS/NZS 4766:2006 for guaranteed peace of mind.

Chemical Grade

Polymaster’s specially formulated PE material grades are certified to safely contain over 2,000 chemicals.

CASE STUDIES

Upgrading the Dungong Wastewater Treatment Plant

Find out how Polymaster was involved in the completion of a $28 million upgrade project to improve Dungong’s water quality.

  • Industry: Waste Water Treatment
  • Application: Clean In Place
  • Product Used: Medium Self Bunded Chemical Tank
C&I - Customer Service Team Member

Applications

What are the applications for Aluminium Chlorohydrate?

Aluminium chlorohydrate (ACH) is a versatile chemical with a wide range of applications across various industries. Here are some of its primary uses:

Aerial shot of a water treatment plant

Water Treatment

Aluminium chlorohydrate is widely used as a coagulant in water purification processes. It helps remove dissolved organic material, suspended particles, and other impurities, resulting in clearer and safer water. This process is essential in both municipal water treatment facilities and industrial wastewater treatment plants.

Cone Bottom tanks inside a factory space

Clean In Place

In various industries, ACH is used in Clean In Place (CIP) systems. CIP is a method of cleaning the interior surfaces of pipes, vessels, and equipment without disassembly. Aluminium chlorohydrate enhances the effectiveness of CIP by coagulating and flocculating impurities, making them easier to remove during the cleaning process.

FAQs

Frequently Asked Questions

Got a question about storing or dosing Aluminium Chlorohydrate? Here’s what our customers ask most — from best-practice storage to safe handling and what to avoid mixing it with.

Aluminium Chlorohydrate is a highly reactive and corrosive chemical that requires special handling and storage. It is important that it is stored within a container that is resistant to corrosive chemicals. This means within a tank or container that is built for the purpose of holding aggressive chemicals.

Store Aluminium Chlorohydrate at room temperature in a dry and well-ventilated area away from direct sunlight.

Use containers made of compatible materials, such as our 7032 grade hexene 1.5SG to store Aluminium Chlorohydrate. Never store in metal containers. It will attack metal resulting in a spill.

Store Aluminium Chlorohydrate separately from other chemicals, particularly bases, which can react with it and cause dangerous reactions.

Ensure that Aluminium Chlorohydrate containers are tightly sealed and labelled with the proper hazard warnings.

Regularly inspect and check your tank for any signs of damage or wear that may occur and get them repaired immediately.

Other alkaline-based chemicals and oxidizing agents may release toxic Chlorine gas if mixed.

Aluminium Chlorohydrate may slowly corrode Iron, Brass, Copper, Aluminium, Mild Steel and Stainless Steel

When it comes to the storage and handling of Aluminium Chlorohydrate it is important that it is handled safely, and that everyone on-site is kept safe. Here are a few guidelines to follow to keep your workplace safe:

Store the chemical in its own designated area, away from other chemicals and direct sunlight. If Aluminium Chlorohydrate is exposed to direct sunlight, it can cause thermal decomposition which may release toxic and/or hazardous gases such as Chlorine gas and Hydrogen Chloride Gas.

With any type of corrosive chemical using the appropriate personal protective equipment (PPE) such as gloves, goggles and face shield is a must, Aluminium Chlorohydrate is no different.

Avoid inhaling Aluminium Chlorohydrate fumes or mist, which can cause respiratory irritation and other health problems.

Always handle Aluminium Chlorohydrate with care and avoid splashing or spilling it.

Do not mix Aluminium Chlorohydrate with any other chemicals or substances without first consulting a qualified professional.

RESOURCES

Chemical Tank Compatibility Chart

This Chemical Compatibility Chart provides a comparison of the chemical resistance of our Specialty Grades of Linear Low Density Polyethylene, High Density Polyethylene and Polypropylene Polymers in different chemical environments.

Chemical Tank Compatibility Chart

Ask a Specialist

Fill in the form below and a specialist will be in touch within 24 hours to discuss your needs and answer any questions.

Ask A Specialist Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Name*

Download Step File

Lorem ipsum dolor sit amet consectetur. Cursus enim dictum pellentesque vulputate elementum at. Adipiscing ut massa praesent.

Download Step File Form

"*" indicates required fields

This field is for validation purposes and should be left unchanged.
Postcode
Country

Cow Popup